Кабельные вводы, уплотнительные кольца, переходники

Кабельные вводы и сопутствующие комплектующие FLEXA

US

Metal connector, safety-type straight, outer thread metric or PG incl. ferrule [brass/plastic], sealing [TPE] or brass thrust collar and O-ring [NBR]

FLEXA US

Material: nickel-plated brass

Temperature: -40°C ... +125°C -40°C ... +250°C with brass thrust collar [MSD]

Prot. rate [acc. to EN 60529]: IP40 - IP66

US2

Metal connector, safety-type straight, metric inner thread, incl. ferrule made of brass and sealing made of TPE or brass thrust collar [MSD]

FLEXA US2

Material: nickel-plated brass

Temperature: -40°C ... +125°C -40°C ... +250°C with brass thrust collar [MSD]

Prot. rate [acc. to EN 60529]: IP40 - IP65

USDR

Metal connector, safety-type straight, turnable metric outer thread incl. ferrule made of brass, sealing made of TPE or brass thrust collar [MSD] and O-ring made of NBR

FLEXA USDR

Material: nickel-plated brass

Temperature: -40°C ... +125°C -40°C ... +250°C with brass thrust collar [MSD]

Prot. rate [acc. to EN 60529]: IP40 - IP65

USZ-M

Metal connector, safety-type straight, metric outer thread, strain relief, incl. ferrule, sealing made of TPE or brass thrust collar [MSD] and O-ring

FLEXA USZ-M

Material: nickel-plated brass

Temperature: -40°C ... +100°C

Prot. rate [acc. to EN 60529]: IP40 - IP65

USZ-EX-M

Metal connector, safety-type straight, metric outer thread, strain relief for application in EX-Area, incl. ferrule, sealing made of TPE or brass thrust collar [MSD] and O-ring made of NBR

FLEXA USZ-EX-M

Material: nickel-plated brass

Temperature: -40°C ... +100°C

Prot. rate [acc. to EN 60529]: IP40

USD

EMC metal connector, straight, outer thread metric or PG, incl. ferrule made of brass and O-Ring made of NBR

FLEXA USD

Material: nickel-plated brass

Temperature: -40°C ... +125°C

Prot. rate [acc. to EN 60529]: IP67

LI

Metal connector, straight, outer thread metric or PG, integrated ferrule made of brass, turnable

FLEXA LI

Material: nickel-plated brass

Temperature: -40°C ... +250°C

Prot. rate [acc. to EN 60529]: IP40

LIF

Metal connector, straight, fixed outer thread metric or PG, integrated ferrule

FLEXA LIF

Material: nickel-plated brass

Temperature: -40°C ... +250°C

Prot. rate [acc. to EN 60529]: IP40

USW

Metal connector, safety-type, 90° elbow outer thread metric or PG, incl. ferrule, sealing or brass thrust collar [MSD] and O-ring

FLEXA USW

Material: USW-M nickel-plated brass USW-P zinc die-casting

Temperature: -40°C ... +125°C -40°C ... +250°C with brass thrust collar [MSD]

Prot. rate [acc. to EN 60529]: IP40 - IP66

USK

Plastic connector, straight, outer thread metric or PG, incl. ferrule and sealing

FLEXA USK

Material: plastics [PP]

Temperature: -10°C ... +110°C

Prot. rate [acc. to EN 60529]: IP54

LKI

Plastic connector, straight, one-part, connecting thread metric or PG, turnable

FLEXA LKI

Material: resistant plastics [PP]

Temperature: -10°C ... +110°C

Prot. rate [acc. to EN 60529]: IP54

USE

Metal connector, safety-type, straight, outer thread metric or PG, incl. ferrule and sealing, UL and SETI approval

FLEXA USE

Material: nickel-plated brass

Temperature: -25°C ... +100°C

Prot. rate [acc. to EN 60529]: IP66

EG

Metal connector, straight outer thread metric or PG, incl. ferulle and sealing, UL and CSA approval

FLEXA EG

Material: zinc die-casting

Temperature: -25°C ... +100°C

Prot. rate [acc. to EN 60529]: IP66

EW 45

Metal connector, elbow 45° outer thread metric or PG, incl. ferrule and sealing, UL and CSA approval

FLEXA EW 45

Material: zinc die-casting

Temperature: -25°C ... +100°C

Prot. rate [acc. to EN 60529]: IP66

EW 90

Metal connector, elbow 90° outer thread metric or PG, incl. ferule and sealing, UL and CSA approval

FLEXA EW 90

Material: zinc die-casting

Temperature: -25°C ... +100°C

Prot. rate [acc. to EN 60529]: IP66

NIMS

Metal conduit olive hexagon wrench surface, fixed outer thread metric or PG, incl. O-Ring

FLEXA NIMS

Material: nickel-plated brass

Temperature: -40°C ... +250°C

Prot. rate [acc. to EN 60529]: IP54 - 65

SGL

Conduit clamp suitable for conduit olive NIMS

FLEXA RQBK90DR

Material: galvanized steel

Temperature: -40°C ... +120°C

MSD

Brass thrust collar suitable for connectors US for grounding and for shielding applications

FLEXA MSD

Material: brass

Temperature: ...+250°C

TED

Sealing for connectors US and protective conduit FLEXAgraff®-SI-ASF

FLEXA TED

Material: PTFE

Temperature: -60°C ... +300°C

EK

Zylindric plastic terminal sleeve for all protective conduit types made of metal and plastic

FLEXA EK

Material: polypropylene

Temperature: -10°C ... +110°C

AK

End cap / transition from tubing to cable

FLEXA AK

Material: TPE

Temperature: -40°C ... +120°C ^+150°C

EEM

Terminal sleeves / ferrules for connectors US and USW as terminal sleeves for protective conduits

FLEXA EEM

Material: brass

Temperature: -40°C ... +250°C

EE

Terminal sleeves / ferrules for connectors US and USW as terminal sleeves for protective conduits

FLEXA EE

Material: brass

Temperature: -40°C ... +250°C

EEK

Terminal sleeves / ferrules for connectors USK as terminal sleeves for protective conduits AIRflex®

FLEXA EEK

Material: plastics

Temperature: -10°C ... +110°C